<?xml version="1.0" encoding="UTF-8" ?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:slash="http://purl.org/rss/1.0/modules/slash/">
	<channel>
		<title><![CDATA[공지사항]]></title>
		<link>https://www.ramedi.kr/xe/notices</link>
		<description><![CDATA[]]></description>
		<language>ko</language>
		<pubDate>Sun, 31 May 2026 13:52:50 +0900</pubDate>
		<lastBuildDate>Sun, 31 May 2026 13:52:50 +0900</lastBuildDate>
		<generator>XpressEngine</generator>
								<item>
			<title><![CDATA[사이버보안(Cybersecurity) 대응과 SBoM(Software Bill of Materials, 소프트웨어 자재 명세서) 관리]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2412</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2412</guid>
						<comments>https://www.ramedi.kr/xe/2412#comment</comments>
									<description><![CDATA[<div class="xe_content"><p>&nbsp;</p>

<div data-hjsonver="1.0" data-jsonlen="25893" id="hwpEditorBoardContent">
<p><strong><span style="color:#696969;">1. 배경</span></strong></p>

<p><span style="color:#696969;">&nbsp; 1) 의료기기 제조사는 미국 등 수출을 위해서는 의료기기 개발에 사용된 구성 요소(오픈소스 포함)에 대한 SBoM을 기반으로 한 취약점</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; 관리가 필요하다.</span></p>

<p><span style="color:#696969;">&nbsp; 2) 소프트웨어 개발에 사용되는 오픈소스와 관련된 취약점이 지속적으로 발생하고 있다.</span></p>

<p><span style="color:#696969;">&nbsp; 3) 소프트웨어 공급망 보안(Software Supply Chain Security)은 더 이상 선택이 아닌 필수이며, SBoM은 소프트웨어 공급망 보안의 </span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; 중요한 도구이다.</span></p>

<p>&nbsp;</p>

<p><strong><span style="color:#696969;">2. SBoM의 기본 요소</span></strong></p>

<p><span style="color:#696969;">&nbsp; 1) 작성자 이름</span></p>

<p><span style="color:#696969;">&nbsp; 2) 타임 스탬프</span></p>

<p><span style="color:#696969;">&nbsp; 3) 소프트웨어 컴포넌트 벤더(공급업체)</span></p>

<p><span style="color:#696969;">&nbsp; 4) 소프트웨어 컴포넌트 이름</span></p>

<p><span style="color:#696969;">&nbsp; 5) 소프트웨어 컴포넌트 버전</span></p>

<p><span style="color:#696969;">&nbsp; 6) 고유 식별자</span></p>

<p><span style="color:#696969;">&nbsp; 7) 관계</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><strong><span style="color:#696969;">3. SBoM 취약점 분석 및 대응</span></strong></p>

<p><span style="color:#696969;">&nbsp; 1) 기본 취약점 식별 및 데이터 수집</span></p>

<p><span style="color:#696969;">&nbsp; 2) 위험 우선순위 설정 및 분석</span></p>

<p><span style="color:#696969;">&nbsp; 3) KEV(Known Exploited Vulnerabilities), VEX(Vulnerability Exploitability eXchange) 적용</span></p>

<p><span style="color:#696969;">&nbsp; 4) 대응 방안 결정 프로세스 적용</span></p>

<p>&nbsp;</p>
</div>

<p><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>4. SBoM의 활용</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) SBoM을 도입해 소프트웨어 개발에 사용된 오픈소스나 보안 업데이트 사항을 관리한다.</span></p>

<p><span style="color:#696969;">&nbsp; 2) SBoM은 기기 내의 소프트웨어에 포함된 컴포넌트와 연관된 위험을 투명하게 제공한다.</span></p>

<p><span style="color:#696969;">&nbsp; 3) 확보된 취약점 정보로부터 영향을 받는 소프트웨어 컴포넌트를 확인하고, SBoM을 활용하여 해당 컴포넌트를 포함하고 있는</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; 의료기기를 식별한다.</span></p>

<p><span style="color:#696969;">&nbsp; 4) SBoM은 견고한 사고 대응 절차와 함께 사용될 경우, 더 나은 사고 관리를 할 수 있도록 도와주는 여러 자원 중 하나이다.</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--><br />
<!--![endif]--><!--![if--></span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>※ 용어</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) SBoM (Software Bill of Materials, 소프트웨어 자재 명세서)</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; 하나 이상의 식별된 컴포넌트와 그 관계 및 기타 관련 정보의 목록</span></p>

<p><span style="color:#696969;">&nbsp; 2) 소프트웨어 공급망 보안 (Software Supply Chain Security)</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; 소프트웨어를 개발･배포하는 전 과정(공급망)에서 악성코드나 취약점이 침투하지 않도록 보호하는 보안 체계를 뜻하며, </span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; 대표적인 보안 강화 방법의 하나가 SBoM(Software Bill of Materials)을 기반으로 한 위험관리임.</span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p>감사합니다.</p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p>&nbsp;</p></div>]]></description>
						<pubDate>Mon, 09 Feb 2026 15:19:37 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[의료기기 수입 및 제조를 위한 교육 훈련(Training Program) 안내]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2400</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2400</guid>
						<comments>https://www.ramedi.kr/xe/2400#comment</comments>
									<description><![CDATA[<div class="xe_content"><div data-hjsonver="1.0" data-jsonlen="19028"><span style="color:#808080;"><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--></span><span style="color:#808080;"><!--[if--><!--[endif]--></span><strong><span style="color:#696969;">1. 의료기기 수입업 진출을 위한 교육 훈련</span></strong></div>

<p><span style="color:#808080;">&nbsp; 1) 교육 목적 : 수입업 진출을 위한 법적 요구사항과 인허가 프로세스의 이해</span></p>

<p><span style="color:#808080;">&nbsp; 2) 교육 대상 : 품질책임자, 품질관리 담당자, 수입업 진출을 준비하는 담당자</span></p>

<p><span style="color:#808080;">&nbsp; 3) 교육 내용</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (1) 의료기기 주요 법령의 요구사항</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (2) 수입품목인허가 프로세스의 이해</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (3) 제조원 GMP 심사 프로세스의 이해</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (4) 품질관리시스템의 이해 및 수립</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (5) 품질관리시스템의 운영 방안(수입업자 준수사항 등)</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (6) 수입통관 프로세스(표준통관예정보고서 발급 등)</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (7) 시판 후 사후관리 등</span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><strong>2. 의료기기 제조업 진출을 위한 교육 훈련</strong></span></p>

<p><span style="color:#808080;">&nbsp; 1) 교육 목적 : 제조업 진출을 위한 법적 요구사항과 인허가 프로세스의 이해</span></p>

<p><span style="color:#808080;">&nbsp; 2) 교육 대상 : 품질책임자, 품질관리 담당자, 제조업 진출을 준비하는 담당자</span></p>

<p><span style="color:#808080;">&nbsp; 3) 교육 내용</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (1) 의료기기 주요 법령의 요구사항</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (2) 제조품목인허가 프로세스의 이해</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (3) 제조원 GMP 심사 프로세스의 이해</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (4) 품질경영시스템의 이해, 수립 및 운영 방안</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (5) 시판 후 사후관리 등</span></p>

<p><span style="color:#808080;"><!--[if-->&nbsp;<!--[endif]--> </span><!--![endif]--><!--![if--></p>

<p><span style="color:#808080;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#808080;"><strong><span style="color:#696969;">3. 제조원 GMP 심사 및 품질경영시스템 유지를 위한 교육 훈련</span></strong></span></p>

<p><span style="color:#808080;">&nbsp; 1) 교육 목적 : GMP 심사의 법적 요구사항 이해와 품질경영시스템 유지를 위한 실무역량 습득 및 강화</span></p>

<p><span style="color:#808080;">&nbsp; 2) 교육 대상 : 품질책임자, 품질관리 담당자</span></p>

<p><span style="color:#808080;">&nbsp; 3) 교육 내용</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (1) 제조 및 품질관리 기준의 법적 요구사항</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (2) 품질경영시스템의 이해, 수립, 운영 및 유지 방안</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (3) GMP 현장 심사를 위한 준비 및 대응 방안</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (4) 제조소 현장에서의 모의심사 수행</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; &nbsp; ① 문서 및 기록상태의 점검 및 개선</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; &nbsp; ② 제조소 환경 점검 및 개선</span></p>

<p><span style="color:#808080;"><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p><span style="color:#808080;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#808080;"><strong><span style="color:#696969;">4. 수입업자 준수사항 등 품질관리의 실행 및 유지를 위한 교육 훈련</span></strong></span></p>

<p><span style="color:#808080;">&nbsp; 1) 교육 목적 : 수입업자 준수사항 등 품질관리의 법적 요구사항 이해와 실무역량 습득 및 강화</span></p>

<p><span style="color:#808080;">&nbsp; 2) 교육 대상 : 품질책임자, 품질관리 담당자</span></p>

<p><span style="color:#808080;">&nbsp; 3) 교육 내용</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (1) 품질관리시스템의 이해</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (2) 품질관리시스템의 운영 방안(수입업자 준수사항 등)</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (3) 수입통관 프로세스(표준통관예정보고서 발급 등)</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; (4) 시판 후 사후관리 등</span></p>

<p><span style="color:#808080;"><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p><span style="color:#808080;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#808080;"><strong><span style="color:#696969;">5. 기타 공통사항</span></strong></span></p>

<p><span style="color:#808080;">&nbsp; 1) 교육 훈련은 의뢰회사에서의 현장 교육으로 진행됩니다.</span></p>

<p><span style="color:#808080;">&nbsp; 2) 교육 과정 및 교육 내용은 의뢰회사의 상황과 요구에 따라 조정(변경)될 수 있습니다.</span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p><span style="color:#808080;"><span style="color:#000000;">감사합니다.</span></span></p>
<!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--></div>]]></description>
						<pubDate>Tue, 08 Jul 2025 17:14:24 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[의료기기 사이버보안(Cybersecurity)의 이해와 적용]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2375</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2375</guid>
						<comments>https://www.ramedi.kr/xe/2375#comment</comments>
									<description><![CDATA[<div class="xe_content"><p><span style="color:#696969;"><strong>1. 목적</strong></span></p>

<p>&nbsp; <span style="color:#696969;">의료기기의 사이버보안 위협사례(해킹, 정보 유출 등)로부터 통신이 가능한 의료기기의 안전관리를 확보하는 데 있다.</span></p>

<p><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></p>

<p><!--[if--><!--[endif]--></p>

<p><span style="color:#696969;"><strong>2. 적용 범위</strong></span></p>

<p><span style="color:#696969;">&nbsp; 유&middot;무선 통신(Wi-Fi, 블루투스, USB, RS-232, LAN 등)을 사용하거나 통신 경로가 존재하는 의료기기에 적용한다.</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> </span><!--![endif]--><!--![if--></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>3. 사이버보안 기본원칙</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 의료기기의 사이버보안을 보장하기 위하여 가용성, 기밀성, 무결성이 준수되어야 한다.</span></p>

<p><span style="color:#696969;">&nbsp; 2) 제조자가 품질경영시스템에서 수립한 위험관리 프로세스 내에서 적용되어야 한다.</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>4. 사이버보안 요구사항</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 식별 및 인증(Identification and Authentication) : 시스템 사용 알림 메시지(IA-08) 등</span></p>

<p><span style="color:#696969;">&nbsp; 2) 사용 통제(Use Control) : 부인 방지(UC-07) 등</span></p>

<p><span style="color:#696969;">&nbsp; 3) 시스템 무결성(System Integrity) : 부트 프로세스 무결성 검증(SI-11) 등</span></p>

<p><span style="color:#696969;">&nbsp; 4) 데이터 기밀성(Data Confidentiality) : 안전한 암호화 사용(DC-03) 등</span></p>

<p><span style="color:#696969;">&nbsp; 5) 이벤트 적시 대응(Timely Response to Events) : 감사 로그에 대한 비인가된 접근 제한(TRE-01)</span></p>

<p><span style="color:#696969;">&nbsp; 6) 자원 가용성(Resource Availability) : 불필요한 기능 비활성화(RA-05) 등</span></p>

<p><br />
<!--![endif]--><!--![if--></p>

<p><!--[if--><!--[endif]--></p>

<p><span style="color:#696969;"><strong>5. 사이버보안의 적용</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 사이버보안 위험관리 과정을 통해 위해요인을 파악하고, 발생 가능한 위해를 최소화 및 차단하기 위한 설계변경 등의</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp;통제조치를 실행한다.</span></p>

<p><span style="color:#696969;">&nbsp; 2) 위험관리 과정에서 식별된 위해요인에 대한 통제조치의 결과를 소프트웨어 검증 및 유효성 확인의 단계에서 검증하며,</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp;소프트웨어 검증 및 유효성 확인의 자료에는 사이버보안 요구사항에 대한 시험 및 검증 절차, 시험 결과를 포함하여야 한다.</span></p>

<p><span style="color:#696969;">&nbsp; 3) 사이버보안 위험관리 문서와 소프트웨어 검증 및 유효성 확인 자료를 바탕으로 사이버보안 요구사항 체크리스트 작성하여,&nbsp;</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp;사이버보안 요구사항이 개발 제품에 적용되었음을 검증한다.</span></p>

<p><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></p>

<p><!--[if--><!--[endif]--></p>

<p><span style="color:#696969;"><strong>6. 허가 및 심사를 위한 사이버보안 제출 자료</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 의료기기 사이버보안 요구사항 체크리스트</span></p>

<p><span style="color:#696969;">&nbsp; 2) 체크리스트의 요구사항에 대한 검증을 확인할 수 있는 자료</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (1) 소프트웨어 검증 및 유효성 확인 자료</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (2) 사이버보안 위험관리 문서</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (3) 성능 시험성적서</span></p>

<p><span style="color:#696969;">&nbsp; 3) 사이버보안 요구사항의 미적용 근거를 확인할 수 있는 자료 (해당되는 경우)</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (1) 사이버보안 위험관리 문서</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (2) 사용설명서</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (3) 설계문서 등</span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p>감사합니다.</p></div>]]></description>
						<pubDate>Tue, 11 Mar 2025 16:14:56 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[의료기기 품질경영시스템을 위한 소프트웨어 밸리데이션(QMS SW Validation)의 이해와 적용]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2355</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2355</guid>
						<comments>https://www.ramedi.kr/xe/2355#comment</comments>
									<description><![CDATA[<div class="xe_content"><p>&nbsp;</p>

<div data-hjsonver="1.0" data-jsonlen="21729" id="hwpEditorBoardContent">
<p><span style="color:#696969;"><strong>1. 개요</strong></span></p>

<p><span style="color:#808080;">품질관리를 통한 의료기기의 안전성 및 유효성 확보를 위하여 품질경영시스템 내에서 사용되는 소프트웨어의 경우, 그 사용에 앞서 해당 소프트웨어의 유효성을 확인하여야 한다.</span></p>

<p><span style="color:#808080;"><!--[if-->&nbsp;<!--[endif]--> </span><!--![endif]--><!--![if--></p>
<!--[if--><!--[endif]-->

<p><span style="color:#696969;"><strong>2. 적용 대상</strong></span></p>

<p><span style="color:#808080;">&nbsp; 1) 품질경영시스템에 사용되는 컴퓨터 소프트웨어</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; 예) 고객 관리 및 피드백에 사용되는 응용프로그램 등</span></p>

<p><span style="color:#808080;">&nbsp; 2) 생산 및 서비스 제공에 사용되는 컴퓨터 소프트웨어</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; 예) 라벨 및 UDI 출력에 사용되는 응용프로그램 등</span></p>

<p><span style="color:#808080;">&nbsp; 3) 규정된 요구사항에 대한 모니터링 및 측정에 사용되는 컴퓨터 소프트웨어</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; 예) 만능재료시험기(UTM)에 사용되는 응용프로그램 등</span></p>

<p><span style="color:#808080;"><!--[if-->&nbsp;<!--[endif]--> </span><!--![endif]--><!--![if--></p>
<!--[if--><!--[endif]-->

<p><span style="color:#696969;"><strong>3. 적용 규격</strong></span></p>

<p><span style="color:#808080;">&nbsp; 1) ISO TR 80002-2:2017</span></p>

<p><span style="color:#808080;">&nbsp; 2) IEC TR 80002-1:2009</span></p>

<p><span style="color:#808080;">&nbsp; 3) ISO 14971(2019) 등</span></p>

<p><span style="color:#808080;"><!--[if-->&nbsp;<!--[endif]--> </span><!--![endif]--><!--![if--></p>
<!--[if--><!--[endif]-->

<p><span style="color:#696969;"><strong>4. 밸리데이션 활동</strong></span></p>

<p><span style="color:#808080;">&nbsp; 1) 프로세스를 명확히 정의하고 밸리데이션 계획을 수립한다.</span></p>

<p><span style="color:#808080;">&nbsp; 2) <strong>프로세스 위험분석</strong>을 통해 문서화 노력의 엄격성 수준을 결정한다.</span></p>

<p><span style="color:#808080;">&nbsp; 3) <strong>소프트웨어 위험분석</strong>을 근거로 공구 상자(Toolbox)에서 밸리데이션 활동을 위한 가장 적합한 공구(소프트웨어의 위험을</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; &nbsp;감소시키고 신뢰를 구축하는 활동)를 찾아내고 선택한다.</span></p>

<p><span style="color:#808080;">&nbsp; 4) 선택한 공구를 활용하여 소프트웨어의 요구사항과 목적이 충족되며, 의도한 사용에 적합하고 믿을 만한 소프트웨어의 </span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; &nbsp;신뢰 수준을 입증하는 밸리데이션 활동을 진행한다.</span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><strong>5. 밸리데이션 보고서</strong></span></p>

<p><strong><span style="color:#808080;">&nbsp;&nbsp;</span></strong><span style="color:#808080;">1) 신뢰-구축 활동의 결과로서, 소프트웨어 관리자는 최종 검토와 승인을 받기 위해서 밸리데이션 보고서를 작성한다.</span></p>

<p><span style="color:#808080;">&nbsp; 2) 밸리데이션의 수행을 위해 결정된 모든 활동을 계획대로 수행하였음을 보여주는 증거를 포함한다.</span></p>

<p><span style="color:#808080;">&nbsp; 3) 밸리데이션 보고서의 검토자는 소프트웨어 관리자가 시스템의 의도한 사용에 대해서 명확한 생각을 가지고 있고, 시스템 </span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; &nbsp;사용과 관련된 모든 위험을 이해하고 있는지 검토한다.</span></p>

<p><span style="color:#808080;">&nbsp; 4) 검토자는 시스템 사용을 허용하기 위해서 요구되는 시스템의 신뢰 수준에 도달하는데 필요한 모든 활동을 수행하였는지 </span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; &nbsp;검토한다.</span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><strong>6. 맺음말</strong></span></p>
<!--[if--><!--[endif]--><!--[if--><!--[endif]-->

<p><span style="color:#808080;">현실적이고 이용 가능한 공구 상자의 모든 공구를 최대한 활용하여 밸리데이션을 진행함으로써 밸리데이션의 완전성을 높이도록 한다.</span></p>

<div data-hjsonver="1.0" data-jsonlen="21729">&nbsp;</div>

<div data-hjsonver="1.0" data-jsonlen="21729">&nbsp;</div>

<div data-hjsonver="1.0" data-jsonlen="21729" id="hwpEditorBoardContent">감사합니다.</div>
</div>

<p>&nbsp;</p>

<p>&nbsp;</p></div>]]></description>
						<pubDate>Fri, 13 Dec 2024 13:54:41 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[의료기기 위험관리(Risk Management)의 이해와 적용]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2342</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2342</guid>
						<comments>https://www.ramedi.kr/xe/2342#comment</comments>
									<description><![CDATA[<div class="xe_content"><p>&nbsp;</p>

<div data-hjsonver="1.0" data-jsonlen="22182" id="hwpEditorBoardContent">
<p><strong><span style="color:#696969;">1. 개요</span></strong></p>

<p><span style="color:#696969;">위험관리는 의료기기의 수명 주기(Life-cycle)에 걸쳐 위험을 분석, 평가, 통제하는 일에 대한 관리정책, 절차 및 실무의 체계적인 적용을 수행함으로써 의료기기와 연관된 위험을 최소화하는 일련의 활동입니다.</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> </span><!--![endif]--><!--![if--></p>
<!--[if--><!--[endif]-->

<p><strong><span style="color:#696969;">2. 적용 규격(국제표준)</span></strong></p>

<p><span style="color:#696969;">ISO 14971:2019, Medical devices - Application of risk management to medical devices</span></p>

<div data-hjsonver="1.0" data-jsonlen="7523" id="hwpEditorBoardContent">&nbsp;</div>
<span style="color:#696969;"><!--![endif]--><!--![if--></span>

<p><span style="color:#696969;"><strong>3. 위험관리의 이해</strong></span></p>

<p><span style="color:#696969;">GMP의 목적은 지속적 개선이고, 궁극적으로는 이를 통한 의료기기의 안전성과 유효성의 확보입니다. 안전성과 위험은 상반되는 개념이지만, 위험이 없는 상태를 나타내는 안전성과 위험을 최소화한 위험관리는 그 맥을 함께하고 있습니다. 바로 이 부분에서 위험관리의 위상을 확인할 수 있습니다.</span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;">사용적합성, SW 밸리데이션도 위험관리의 한 부분이며, 거의 모든 부분이 깊이 들여다 보면 위험관리와 연관되는 부분임을 알 수 있습니다. 사용적합성은 사용오류, SW 밸리데이션은 SW의 작동오류, 교육훈련은 인원에 대한, 포장 밸리데이션은 포장에 대한 위험관리인 것입니다.</span></p>
<span style="color:#696969;"><!--[if--><!--[endif]--></span>

<div data-hjsonver="1.0" data-jsonlen="13034" id="hwpEditorBoardContent">&nbsp;</div>
<span style="color:#696969;"><!--![endif]--><!--![if--></span>

<p><span style="color:#696969;"><strong>4. 위험관리의 주요 프로세스</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 위험분석</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 위험요인을 식별하고 위험을 산정하기 위한 유용한 정보의 체계적인 사용</span></p>

<p><span style="color:#696969;">&nbsp; 2) 위험평가</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 위험의 허용가능성을 결정하기 위해, 정해진 위험 기준과 산정된 위험을 비교하는 과정</span></p>

<p><span style="color:#696969;">&nbsp; 3) 위험통제</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 위험을 규정된 수준 이하로 줄이거나 그러한 수준 이내로 유지하기 위하여 의사결정을 도출하고 예방조치를 구현하는</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 프로세스</span></p>

<p><span style="color:#696969;">&nbsp; 4) 생산 및 생산 후 활동</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 생산 및 생산 후 단계에서 제품과 관련된 정보를 적극적으로 수집하고 검토하기 위한 활동</span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><strong>5. 맺음말</strong></span></p>

<p><span style="color:#696969;">거의 모든 영역과 깊은 연관성을 맺고 있는 매우 중요하고 근간이 되는 <strong>위험분석(위험관리)</strong>과 <strong>내부감사</strong> 및 <strong>GAP 분석</strong>을 판단의 근거 및 객관적 검증을 통한 전반적 문제 해결을 위한 도구로 적극적으로 활용할 수 있기를 바랍니다.</span></p>

<div data-hjsonver="1.0" data-jsonlen="8313" id="hwpEditorBoardContent">&nbsp;</div>

<div data-hjsonver="1.0" data-jsonlen="8313">
<p><span style="color:#696969;">※ 수명주기 (Life-cycle) : 최초 개발 단계에서 최종 폐기까지의 의료기기 수명의 모든 단계</span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><span style="color:#000000;">감사합니다.</span></span></p>
</div>
</div>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p>&nbsp;</p></div>]]></description>
						<pubDate>Mon, 22 Jul 2024 13:42:02 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[의료기기 소프트웨어 밸리데이션(SW Validation)의 이해와 적용]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2318</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2318</guid>
						<comments>https://www.ramedi.kr/xe/2318#comment</comments>
									<description><![CDATA[<div class="xe_content"><p><span style="color:#696969;"><!--[if--><!--[endif]--></span><span style="color:#696969;"><strong><span style="color: rgb(0, 0, 0);">1. 소프트웨어 밸리데이션(SW Validation)의 개요</span></strong></span></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span><span style="color:#696969;"><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--></span><span style="color:#696969;"><!--[if--><!--[endif]--></span><span style="color:#696969;"><!--[endif]--> <!--![endif]--><!--![if--></span><span style="color:#696969;">소프트웨어 밸리데이션은 이미 수행해 오던 위험관리의 보다 세분화된 한 부분으로, 여러 위험요소 중에서 특별히 소프트웨어에 의해 발생할 수 있는 위험을 소프트웨어 밸리데이션을 통해 줄여보자는 것으로, Software life-cycle processes에 관한 규격인 IEC 62304의 요구사항에 따라 SW 개발 수명주기의 다양한 단계에서 계획, 실행되는 <strong>연속적인 활동(Activity)과 작업(Task)의 산출물</strong>을 바탕<strong>으로</strong> 소프트웨어의 요구사항(사용목적)이 충족되고 있음을 객관적 증거로 입증하고 문서화하는 일련의 활동이다.</span></p>

<p>&nbsp;</p>

<p><strong><span style="color:#696969;">2. 적용 규격(국제표준)</span></strong></p>

<p><span style="color:#696969;">&nbsp; &bull; IEC 62304(2006+AMDI:2015) : Medical device software - Software life-cycle processes</span></p>

<p><span style="color:#696969;">&nbsp; &bull; General Principles of Software Validation (2002) : FDA Guidance</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><strong><span style="color:#696969;">3. 일반 요구사항</span></strong></p>

<p><span style="color:#696969;">&nbsp; 1) 운영체계, 프로그래밍 언어 등의 소프트웨어 개발환경을 소프트웨어 개발 계획서(SW Development Plan)에 상세히 기술한다.</span></p>

<p><span style="color:#696969;">&nbsp; 2) 시스템 시험을 통하여 개발된 소프트웨어가 요구사항에 적합함을 최종적으로 입증하여야 한다.</span></p>

<p><span style="color:#696969;">&nbsp; 3) IEC 62304의 요구사항을 준수하며, 그에 따라 생성된 산출물을 바탕으로 진행한다.</span></p>

<p>&nbsp;</p>

<p><strong><span style="color:#696969;">4. 소프트웨어의 안전등급 분류</span></strong></p>

<p><span style="color:#696969;">&nbsp; 1) IEC 62304 및/또는 FDA 가이드라인에 따라 소프트웨어의 안전등급을 등급 A(Minor), 등급 B(Moderate), 등급 C(Major)로</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp;분류한다.</span></p>

<p><span style="color:#696969;">&nbsp; 2) 분류된 소프트웨어의 안전등급에 비례하여 소프트웨어 밸리데이션 활동에 대한 문서화의 수준을 진행한다.</span></p>

<p><span style="color:#696969;">&nbsp; 3) 소프트웨어의 안전등급 분류는 위험의 심각도만을 기준으로 판단한다. (위험의 발생가능성은 100%인 것으로 간주)</span></p>

<p>&nbsp;</p>

<p><strong><span style="color:#696969;">5. 소프트웨어 밸리데이션의 문서화</span></strong></p>

<p><span style="color:#696969;">&nbsp; 1) 소프트웨어 개발 계획서(SW Development Plan)</span></p>

<p><span style="color:#696969;">&nbsp; 2) 소프트웨어 밸리데이션 보고서(SW Validation Report)</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (1) Level of Concern</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (2) Software Description</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (3) Device Hazard Analysis</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (4) Software Requirement Specification (SRS)</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (5) Architecture Design Chart (ADC)</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (6) Software Design Specification (SDS)</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (7) Traceability Analysis</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (8) Software Development Environment Description</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (9) Software Verification, Validation Documentation</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (10) Revision Level History</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (11) Unsolved Anomalies</span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p>감사합니다.</p></div>]]></description>
						<pubDate>Tue, 07 May 2024 11:00:09 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[의료기기 사용적합성 엔지니어링 프로세스(Usability Engineering Process)의 이해와 적용]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2137</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2137</guid>
						<comments>https://www.ramedi.kr/xe/2137#comment</comments>
									<description><![CDATA[<div class="xe_content"><p><strong><span style="color:#696969;">1. 사용적합성(Usability)의 개요</span></strong></p>

<p><span style="color:#696969;">사용적합성은 이미 수행해 오던 위험관리의 보다 세분화된 한 부분으로, 여러 위험요소 중에서 특별히 사용자에 의해 발생할 수 있는 위험을 사용적합성 엔지니어링 프로세스의 운영을 통해 줄여보자는 것으로, <strong>사용자 인터페이스</strong>를 중심으로 한 사용 가능한 부분에 대한 다각적인 평가를 의미한다.</span></p>

<div data-hjsonver="1.0" data-jsonlen="6860" id="hwpEditorBoardContent">&nbsp;</div>

<div data-hjsonver="1.0" data-jsonlen="6860">
<p><strong><span style="color:#696969;">2. 적용 규격(국제표준)</span></strong></p>

<p><span style="color:#696969;">&bull; IEC 62366-1:2015/AMD1:2020, Medical device - Part 1: Application of usability engineering to medical devices</span></p>

<p><span style="color:#696969;">&bull; IEC TR 62366-2:2016, Medical device - Part 2: Guidance on the Application of usability engineering to medical devices</span></p>

<div data-hjsonver="1.0" data-jsonlen="6925" id="hwpEditorBoardContent">&nbsp;</div>

<div data-hjsonver="1.0" data-jsonlen="6925">
<p><strong><span style="color:#696969;">3. 사용적합성 엔지니어링 프로세스</span></strong></p>

<p><span style="color:#696969;">&nbsp; 1) 사용 사양서 준비</span></p>

<p><span style="color:#696969;">&nbsp; 2) 안전성 및 잠재적 사용오류와 관련된 사용자 인터페이스 특성 식별</span></p>

<p><span style="color:#696969;">&nbsp; 3) 알려져 있거나 예측 가능한 위해요인과 위해상황 식별</span></p>

<p><span style="color:#696969;">&nbsp; 4) 위해요인 관련 사용 시나리오의 식별 및 기술</span></p>

<p><span style="color:#696969;">&nbsp; 5) 총괄평가를 위한 위해요인 관련 사용 시나리오의 선택</span></p>

<p><span style="color:#696969;">&nbsp; 6) 사용자 인터페이스 사양서 수립</span></p>

<p><span style="color:#696969;">&nbsp; 7) 사용자 인터페이스 평가 계획 수립</span></p>

<p><span style="color:#696969;">&nbsp; 8) 사용자 인터페이스 설계, 구현 및 형성평가 수행</span></p>

<p><span style="color:#696969;">&nbsp; 9) 사용자 인터페이스의 사용성에 대한 총괄평가 수행</span></p>

<p><span style="color:#696969;">&nbsp; 10) 기원이 알려지지 않은 사용자 인터페이스</span></p>

<div data-hjsonver="1.0" data-jsonlen="9205" id="hwpEditorBoardContent">&nbsp;</div>

<div data-hjsonver="1.0" data-jsonlen="9205">
<p><span style="color:#696969;"><strong>4. 사용적합성 평가</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 형성평가</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (1) 설계개발의 중간 단계에서 사용자 인터페이스를 확정하기 전에 실시하는 평가로, 평가에서 확인한 사용자 의견과 검토 </span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; &nbsp; 결과를 반영하여 사용자 인터페이스를 확정하기 위해 수행하는 평가</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (2) 형성평가의 목적은 사용오류 등의 문제점을 찾아내는 것으로, 최소 2회의 형성평가가 권장되며, 마지막 형성평가는 </span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Usability Test 방식을 적용할 것이 권장된다.</span><br />
<!--![endif]--><!--![if--></p>
<!--[if--><!--[endif]-->

<p><span style="color:#696969;">&nbsp; 2) 총괄평가</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (1) 형성평가를 통해 확정한 사용자 인터페이스를 사용자가 사용오류 없이 정말로 잘 사용할 수 있는지를 설계검증 단계에서</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; &nbsp; 최종적으로 검증하는 평가</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (2) 총괄평가는 문제가 없거나 감소 되었음을 입증(확인)하는 것으로, 적합한 이유가 없는 한, 총괄평가는 Usability Test로 </span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; &nbsp; 실시하며, 1회 이상의 총괄평가가 요구된다.</span></p>

<div data-hjsonver="1.0" data-jsonlen="8518" id="hwpEditorBoardContent">&nbsp;</div>
<span style="color:#696969;"><!--![endif]--><!--![if--></span>

<p><span style="color:#696969;"><strong>5. 사용적합성의 주기적 검토</strong></span></p>

<p><span style="color:#696969;">수행한 사용적합성의 후속 조치로 최소 연 1회의 주기로 생산 및 생산 후 정보 등을 활용한 <strong>주기적 검토</strong>를 수행하여 변경사항의 유무를 검토한다. 검토 내용은 회의록 등 정해진 양식에 기록하여 관리하며, 검토 결과는 사용설명서 등 관련 문서를 통해 적극적으로 업데이트(Update)되어야 한다.</span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<div data-hjsonver="1.0" data-jsonlen="6843">감사합니다.</div>
</div>
</div>
</div></div>]]></description>
						<pubDate>Tue, 12 Mar 2024 18:01:00 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[위험기반 접근방식의 적용을 위한 품질경영시스템 내의 프로세스 위험분석과 위험분석 절차서]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2118</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2118</guid>
						<comments>https://www.ramedi.kr/xe/2118#comment</comments>
									<description><![CDATA[<div class="xe_content"><p>&nbsp;</p>

<div data-hjsonver="1.0" data-jsonlen="19280" id="hwpEditorBoardContent"><span style="color:#696969;"><strong>1. 개요</strong></span></div>

<p><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p><span style="color:#696969;">품질경영시스템 내의 모든 프로세스에 대한 위험을 분석함으로써, 품질경영시스템의 근간인 <strong>위험기반 접근 방법</strong>(Risk Based </span></p>

<p><span style="color:#696969;">Approach)을 적용할 수 있는 토대를 마련한다. 이러한 프로세스 위험분석 과정은 문서화 된 <strong>프로세스 위험분석 절차서</strong>에 따라</span></p>

<p><span style="color:#696969;">수행되어야 한다.</span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><!--[if--></span></p>

<p><span style="color:#696969;"><strong>2. 적용 범위</strong></span></p>

<p><span style="color:#696969;">효율적이고 원활한 품질경영시스템의 운영을 위하여 구매관리, 교육훈련 등 품질경영시스템 내의 모든 프로세스의 위험분석에</span></p>

<p><span style="color:#696969;">적용한다.</span></p>

<p><span style="color:#696969;">&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>3. 일반사항</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 효율적이고 원활한 품질경영시스템의 운영을 위해 프로세스에 포함된 위험이 결정되어야 한다.</span></p>

<p><span style="color:#696969;">&nbsp; 2) 품질팀장은 관련 팀장 및 위험관리 담당자와 함께 프로세스 위험분석 평가의 업무를 주관하여 진행한다.</span></p>

<p><span style="color:#696969;">&nbsp; 3) 프로세스 위험분석 결과에 따라, 위험기반 접근 방법이 적용된 각 프로세스의 위험기반 통제 방법과 관리 방법은</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp;해당 절차서에 그 내용을 문서화 하여 관리한다.</span></p>

<p><span style="color:#696969;">&nbsp; 4) 프로세스의 중대한 변경이 예상되는 경우, 관련 팀장 및 위험관리 담당자는 변경사항이 미치는 위험분석에 대한 총괄적</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp;영향평가를 수행한다.</span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><strong>4. 프로세스 위험분석의 주기적 검토</strong></span></p>

<p><span style="color:#696969;">품질팀장은 최소 연 1회의 주기로 기존 위험분석 평가 내용의 확인 및 새로운 프로세스 변경사항의 유무를 검토하며, 변경사항이 있는 경우, 변경사항이 미치는 위험분석에 대한 <strong>총괄적 영향평가</strong>를 수행한다.<br />
<!--![endif]--><!--![if--></span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>5. 검토 결과의 반영</strong></span></p>

<p><span style="color:#696969;">검토 내용은 회의록 등 정해진 양식에 기록하여 관리하며, 검토 결과는 품질경영시스템, 제품 및 관련 문서를 통해 적극적으로</span></p>

<p><span style="color:#696969;">업데이트(Update)되어야 한다.</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;">※ <strong>위험기반 접근 방법</strong>(Risk Based Approach)</span></p>

<p><span style="color:#696969;">품질경영시스템 내의 프로세스에 대한 위험을 결정하고 파악하여, 품질경영시스템에 필요한 모든 프로세스를 <strong>위험기반 통제를</strong></span></p>

<p><span style="color:#696969;"><strong>통해 관리</strong>하는 방법</span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><span style="color:#000000;">감사합니다.</span></span></p></div>]]></description>
						<pubDate>Mon, 01 Jan 2024 23:48:06 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[의료기기 GMP(품질경영시스템, 제조 및 품질관리 기준) 적합인정 심사]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2105</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2105</guid>
						<comments>https://www.ramedi.kr/xe/2105#comment</comments>
									<description><![CDATA[<div class="xe_content"><p style="text-align: justify;">&nbsp;</p>

<p><strong><span style="color:#696969;">1. GMP(품질경영시스템)에 대한 이해</span></strong></p>

<p><span style="color:#696969;">GMP 심사는 &lsquo;의료기기 제조 및 품질관리기준&rsquo;이라는 고시의 요구사항에 적합한 품질경영시스템을 유지하고 있는지를 제조소의 시설과 품질문서 및 기록물을 통하여 확인하는 과정이다. 따라서 품질매뉴얼 및 품질절차서의 전체적인 큰 흐름을 확실히 이해하고 있어야 하며, 이해한 내용을 바탕으로 자사의 제조공정, 인력 현황 및 규모에 맞는 자사만의 품질경영시스템을 구축하여 상시 적절히 운영될 수 있도록 관리하여야 한다.</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> </span><!--![endif]--><!--![if--></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>2. 심사 대상</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 의료기기 제조 및 수입 품목허가(인증, 신고)를 하고자 하는 자</span></p>

<p><span style="color:#696969;">&nbsp; 2) 임상시험용 의료기기를 제조 또는 수입하고자 하는 자</span></p>

<p><span style="color:#696969;">&nbsp; 3) 적합성 인정 및 정기심사를 받고자 하는 의료기기 제조 및 수입업자</span></p>

<p><br />
<!--![endif]--><!--![if--></p>

<p><!--[if--><!--[endif]--></p>

<p><strong><span style="color:#696969;">3. 심사 구분</span></strong></p>

<p><span style="color:#696969;">&nbsp; 1) 최초심사 : 제조소가 기준에 적합함을 인정받기 위해 최초로 받는 심사</span></p>

<p><span style="color:#696969;">&nbsp; 2) 추가심사 : 제조소별로 다른 품목군의 의료기기를 추가하는 경우 받는 심사</span></p>

<p><span style="color:#696969;">&nbsp; 3) 변경심사 : 제조소의 소재지 변경에 따라 적합성인정을 새로이 받는 심사</span></p>

<p><span style="color:#696969;">&nbsp; 4) 정기심사 : 제조소가 품목군별로 3년마다 받는 1회의 심사</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> </span><!--![endif]--><!--![if--></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>4. 심사 신청</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 신청서에 구비서류를 첨부하여 품질관리 심사기관에 심사를 신청</span></p>

<p><span style="color:#696969;">&nbsp; 2) 정기심사의 경우 적합인정서에 기재된 유효기간이 만료되는 날로부터 90일 전까지 신청</span></p>

<p><span style="color:#696969;">&nbsp;<!--[if--></span></p>

<p><!--[endif]--><!--![endif]--><!--![if--></p>

<p><!--[if--><!--[endif]--></p>

<p><strong><span style="color:#696969;">5. GMP 심사를 위한 주요 준비 및 검토사항</span></strong></p>

<p><span style="color:#696969;">&nbsp; 1) 품질경영시스템 전반에 걸친 위험기반 접근(Risk Based Approach) 방식의 적용</span></p>

<p><span style="color:#696969;">&nbsp; 2) 위험기반 접근방식의 적용을 위한 품질경영시스템 내의 프로세스 위험분석 수행</span></p>

<p><span style="color:#696969;">&nbsp; 3) 품질경영시스템, 생산 및 서비스 제공, 모니터링 및 측정에 사용되는 소프트웨어의 유효성 확인(Validation)</span></p>

<p><span style="color:#696969;">&nbsp; 4) 품질매뉴얼, 품질절차서(양식) 및 제품표준서 등 품질문서의 적절성</span></p>

<p><span style="color:#696969;">&nbsp; 5) 제조단위별 품질관리 기록 유지 및 이를 통한 제품과 제조 및 측정 장비에 대한 추적성 확보</span></p>

<p><span style="color:#696969;">&nbsp; 6) 제조기록서 및 성적서 등 품질관리 기록을 통한 사용 장비, 작업조건, 공정별 내용의 명확한 확인 및 검증</span></p>

<p><span style="color:#696969;">&nbsp; 7) 위험관리, 사용적합성, (설계)소프트웨어 밸리데이션 등의 수행 및 그 결과에 따른 사용설명서 등 관련 문서의 적극적 Update</span></p>

<p><span style="color:#696969;">&nbsp; 8) 경영검토, 내부감사, 데이터분석, 고객만족도 조사, 교육훈련 등의 주기적 실시</span></p>

<p><span style="color:#696969;">&nbsp; 9)&nbsp;특수 공정을 포함한 각종 유효성 확인(Validation) 수행 자료</span></p>

<p><span style="color:#696969;">&nbsp; 10) 외주업체에 대한 서면 품질합의서의 작성 및 유지</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> </span><!--![endif]--><!--![if--></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>6. 모의심사를 통한 교육 및 점검</strong></span></p>

<p><span style="color:#696969;">GMP 심사에 앞서 모의심사를 진행하여 자사의 품질경영시스템을 점검하고, 부족한 부분을 정리하여 교육훈련의 자료로 활용하는 것도 GMP 심사를 대비하는 좋은 방법이다.</span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;">※ 품질매뉴얼 : 제조업자의 품질경영시스템을 규정한 문서로 개별 조직의 규모 및 복잡성에 맞도록 세부사항 및 요구사항을</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 기술한 문서</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp;품질절차서&nbsp;: 품질매뉴얼을 보조하는 문서로서 품질경영시스템의 활동 수행에 필요한 책임과 권한, 절차, 자원 등에 관한 </span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 내용을 체계적으로 담고 있는 문서</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp;제품표준서 : 의료기기의 품목 또는 모델별로 규격, 제조공정, 제조기준, 설치 등 제품의 설계부터 출하(설치)까지의 </span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 전 제조공정에 대한 상세한 정보를 포함한 문서</span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><span style="color:#000000;">감사합니다.</span></span></p>

<p><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--></p>

<p style="text-align: justify;"><!--[endif]--><!--![endif]--><!--![if--></p>

<div data-hjsonver="1.0" data-jsonlen="22255" style="text-align: justify;">
<p style="text-align: justify;">&nbsp;</p>
</div>

<p style="margin-left: 77.2pt; text-align: justify;">&nbsp;</p>

<p style="text-align: justify;">&nbsp;</p>

<p style="text-align: justify;">&nbsp;</p></div>]]></description>
						<pubDate>Mon, 20 Nov 2023 13:56:09 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[생물학적 평가제도와 생물학적 평가 보고서(Biological Evaluation Report, BER)]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2090</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2090</guid>
						<comments>https://www.ramedi.kr/xe/2090#comment</comments>
									<description><![CDATA[<div class="xe_content"><p><strong><span style="color:#696969;">1. 개요</span></strong></p>

<p style="text-align: justify;"><span style="color:#696969;">국내는 생물학적 안전에 관한 자료로써 생물학적 시험성적서를 제출하고 있으나 미국, 유럽 등에서는 생물학적 안전을 종합적으로 평가한 생물학적 평가 보고서(Biological Evaluation Report, BER)를 제출하는 상황이다. 따라서 생물학적 안전에 관한 자료의 인정 범위에 대한 국제 조화가 요구되고 있으며, 이를 위하여 생물학적 평가 보고서를 기반으로 하는 생물학적 평가제도의 도입이 요구되는 상황이다.</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> </span><!--![endif]--><!--![if--></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>2. 추진 계획</strong></span></p>

<p style="text-align: justify;"><span style="color:#696969;">생물학적 안전에 관한 자료의 인정 범위에 동등 이상의 국제규격을 포함하도록 고시가 개정될 예정이며, 기존 제도(시험성적서 제출)의 병행과 더불어 4등급 의료기기부터 생물학적 평가 보고서(BER)를 기반으로 하는 생물학적 평가제도의 도입을 우선적 실시 후, 단계적인 확대 추진이 예정(2024년~)되고 있다.</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>3. (생물학적 평가 보고서 기반) 생물학적 평가의 주요 내용</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 의료기기의 생체적합성 평가를 위해서는 생물학적 안전성 평가를 수행하여야 하며, 의료기기의 생물학적 안전성 평가는 국제</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp;시험규격인 ISO 10993 Series 규격에 따라 수행되어야 한다.</span></p>

<p><span style="color:#696969;">&nbsp; 2) 의료기기의 생물학적 평가는 위험관리 활동 중 하나이기 때문에 위험관리 계획에 생물학적 평가계획이 포함되어야 한다.</span></p>

<p style="text-align: justify;"><span style="color:#696969;">&nbsp; 3) 원재료에 대한 물리적 및 화학적 정보(특성)는 평가를 위한 필수자료이며, 시험성적서 외에 기존 제품과의 화학적 동등성 </span></p>

<p style="text-align: justify;"><span style="color:#696969;">&nbsp; &nbsp; &nbsp;입증을 통한 생물학적 안전성의 입증 요구가 증대되고 있다.</span></p>

<p style="text-align: justify;"><span style="color:#696969;">&nbsp; 4) 이미 확보한 정보(문헌 자료, 자사 데이터 등)를 평가하여 적절한 시험을 설계하기 위한 갭 분석(Gap analysis)을 수행한다.</span></p>

<p style="text-align: justify;"><span style="color:#696969;">&nbsp; 5) 정보가 충분하지 않아 기존 지식을 통한 위험산정이 어려운 경우, 적절한 위험평가 또는 정량화를 위해 화학적 특성화, </span></p>

<p style="text-align: justify;"><span style="color:#696969;">&nbsp; &nbsp; &nbsp;물리적 특성화 및/또는 필요한 지식을 도출할 수 있는 생물학적 시험이 필요할 수 있다.</span></p>

<p style="text-align: justify;"><span style="color:#696969;">&nbsp; 6) 위험 완화를 위한 동물 시험은 더 이상의 사용할 수 있는 대안적 조치(기존 지식의 검토, 화학적 및 물리적 특성 분석, 체외 </span></p>

<p style="text-align: justify;"><span style="color:#696969;">&nbsp; &nbsp; &nbsp;평가 또는 대안적 완화 수단 등)가 없는 경우에 실시해야 한다.</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;</span></p>

<p><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>4. 맺음말</strong></span></p>

<p style="text-align: justify;"><span style="color:#696969;">생물학적 평가 보고서(BER)를 기반으로 하는 생물학적 평가제도가 도입된다는 것은 생물학적 안전에 관한 자료에 의한 생물학적 안전성 평가가 단편적 시험에서 문헌, 기존 자료, 실제 시험성적서 등을 포함한 종합적(전체적) 평가로 전환됨을 의미한다. 따라서 의료기기 수입 및 제조업체에서는 교육 프로그램, 가이드라인 등을 통하여 이에 대한 전문성 함양 및 역량 강화에 주의를 기울여야 한다.</span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><strong>※ 생물학적 평가 보고서&nbsp;</strong>(Biological Evaluation Report, BER)</span></p>

<p style="text-align: justify;"><span style="color:#696969;">인체에 접촉하는 의료기기에 대한 위험관리 과정(ISO 14971에 의거)을 통해 계획에 따라 생물학적 위해요인을 식별하고, 생물학적 위험을 예상하며 그 수용 가능성을 종합적으로 평가한 보고서</span></p>

<p style="text-align: justify;">&nbsp;</p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><span style="color:#000000;">감사합니다.</span></span></p></div>]]></description>
						<pubDate>Wed, 11 Oct 2023 23:10:42 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[의료기기의 생물학적 안전성 평가 (Biological Safety Assessment)]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2054</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2054</guid>
						<comments>https://www.ramedi.kr/xe/2054#comment</comments>
									<description><![CDATA[<div class="xe_content"><p><span style="color:#696969;"><strong>1. 개요</strong></span></p>

<p><span style="color:#696969;">생물학적 평가는 광범위한 위험관리 과정의 맥락에서 설정되는 설계검증 활동으로, 의료기기의 제조에 사용되는 원재료(완제품, 분해 산물 등 포함), 첨가제 및 가공 보조제 성분의 특성과 비임상시험, 임상시험, 시판 후 발생하는 부작용 등이 독성학적으로 고려되어야 한다.</span></p>

<p>&nbsp;</p>

<p><strong><span style="color:#696969;">2.생물학적 안전성 평가 (Biological Safety Assessment)</span></strong></p>

<p><span style="color:#696969;">생물학적 안전성 평가에는 다음 사항이 포함되어야 한다.</span></p>

<p><span style="color:#696969;">&nbsp; 1) 의료기기에 대한 일반적인 설명</span></p>

<p><span style="color:#696969;">&nbsp; 2) 의료기기의 생물학적 평가를 위한 전략 및 계획한 내용</span></p>

<p><span style="color:#696969;">&nbsp; 3) 위험관리 계획에 따라 목적을 달성하기 위한 허용된 원재료를 결정하기 위한 기준</span></p>

<p><span style="color:#696969;">&nbsp; 4) 재료 특성 규명의 적절성</span></p>

<p><span style="color:#696969;">&nbsp; 5) 시험의 선택, 생략에 대한 근거</span></p>

<p><span style="color:#696969;">&nbsp; 6) 기존 자료 및 시험 결과의 해석</span></p>

<p><span style="color:#696969;">&nbsp; 7) 생물학적 평가를 완료하기 위한 추가 자료의 필요성</span></p>

<p><span style="color:#696969;">&nbsp; 8) 의료기기에 대한 전반적인 생물학적 안전성에 대한 결론</span></p>

<p>&nbsp;</p>

<p><strong><span style="color:#696969;">3. 생물학적 안전성 평가 보고서 (Biological Safety Assessment Report)</span></strong></p>

<p><span style="color:#696969;">물리적 및 화학적 정보(특성)를 기반으로 한 원재료의 특성 분석을 통한 위험분석 결과와 사용 이력을 바탕으로 생물학적 안전성을 증명하는 위험관리 기반의 의료기기 생물학적 평가를 최신 표준(ISO 10993-1:2018 등)을 반영하여 수행하며, 그 내용과 평가 결과를 생물학적 안전성 평가 보고서에 문서화한다.</span></p>

<p>&nbsp;</p>

<p><strong><span style="color:#696969;">4. 생물학적 안전성 재평가를 고려해야 하는 경우</span></strong></p>

<p><span style="color:#696969;">&nbsp; 1) 제품 원재료의 공급처나 사양의 변경</span></p>

<p><span style="color:#696969;">&nbsp; 2) 조성, 공정, 1차 포장 또는 멸균 방법에 대한 변경</span></p>

<p><span style="color:#696969;">&nbsp; 3) 저장 중인 완제품의 변화</span></p>

<p><span style="color:#696969;">&nbsp; 4) 제품의 사용목적 변경</span></p>

<p><span style="color:#696969;">&nbsp; 5) 의료기기 사용 시 부작용이 발생할 수 있다는 증거가 있는 경우</span></p>

<p>&nbsp;</p>

<p><strong><span style="color:#696969;">5. 맺음말</span></strong></p>

<p><span style="color:#696969;">생물학적 평가의 올바른 수행을 위해서는 평가에 적합한 전략을 결정하고, 다양한 자료를 엄격하게 평가하며, 추가적인 생물학적 시험의 필요성을 정확하게 판단할 수 있어야 한다. 또한, 제조자는 원재료의 성질(화학적, 독성학적, 물리적, 전기적, 형태적, 기계적 성질 등)과 특성이 사용목적에 적합한가를 우선적으로 고려하여야 한다.</span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p>감사합니다.</p></div>]]></description>
						<pubDate>Tue, 30 May 2023 11:50:04 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[GMP(품질경영시스템, ISO 13485) 내에서의 소프트웨어 밸리데이션]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2016</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2016</guid>
						<comments>https://www.ramedi.kr/xe/2016#comment</comments>
									<description><![CDATA[<div class="xe_content"><p><span style="color:#696969;"><strong>1. 적용 대상</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 품질경영시스템에 사용되는 컴퓨터 소프트웨어</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 예) 고객 관리 및 피드백에 사용되는 응용프로그램 등</span></p>

<p><span style="color:#696969;">&nbsp; 2) 생산 및 서비스 제공에 사용되는 컴퓨터 소프트웨어</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 예) 라벨 및 UDI 출력에 사용되는 응용프로그램 등</span></p>

<p><span style="color:#696969;">&nbsp; 3) 규정된 요구사항에 대한 모니터링 및 측정에 사용되는 컴퓨터 소프트웨어</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 예) 만능재료시험기(UTM)에 사용되는 응용프로그램 등</span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><strong>2. 적용 규격</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) ISO TR 80002-2:2017</span></p>

<p><span style="color:#696969;">&nbsp; 2) IEC TR 80002-1:2009</span></p>

<p><span style="color:#696969;">&nbsp; 3) ISO 14971(2019) 등</span></p>

<div data-hjsonver="1.0" data-jsonlen="18061" id="hwpEditorBoardContent">&nbsp;</div>

<p><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>3. 소프트웨어 밸리데이션의 산출물 (결과물)</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 소프트웨어 밸리데이션 계획서</span></p>

<p><span style="color:#696969;">&nbsp; 2) 소프트웨어 밸리데이션 보고서</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>4. 소프트웨어 밸리데이션 보고서의 주요 내용</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 일반적 설명 및 요구사항</span></p>

<p><span style="color:#696969;">&nbsp; 2) 위험관리 프로세스</span></p>

<p><span style="color:#696969;">&nbsp; 3) 밸리데이션 태스크(Task)</span></p>

<p><span style="color:#696969;">&nbsp; 4) 밸리데이션 보고서</span></p>

<p><span style="color:#696969;">&nbsp; 5) 유효성 재확인</span></p>

<p><span style="color:#696969;">&nbsp; 6) 밸리데이션의 승인</span></p>

<p><span style="color:#696969;">&nbsp; 7) 첨부문서 등</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><strong>5. 기타 사항</strong></span></p>

<p style="margin-left:10.0pt;"><span style="color:#696969;">소프트웨어 밸리데이션에 대한 절차서가 요구되며, 절차서에 따라 소프트웨어 밸리데이션 계획서가 작성되고,</span></p>

<p style="margin-left:10.0pt;"><span style="color:#696969;">그에 따라 소프트웨어 밸리데이션 활동이 수행되어야 합니다.</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#000000;">감사합니다.</span></p></div>]]></description>
						<pubDate>Tue, 13 Dec 2022 21:16:38 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[GMP(품질경영시스템, ISO 13485) 교육훈련 안내]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/2011</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/2011</guid>
						<comments>https://www.ramedi.kr/xe/2011#comment</comments>
									<description><![CDATA[<div class="xe_content"><p><span style="color:#A9A9A9;"><span style="color:#808080;"><!--[if--><!--[endif]--></span></span><span style="color:#A9A9A9;"><span style="color:#808080;"><span style="color: rgb(105, 105, 105);">의료기기 GMP의 수립, 실행 및 유지와 관련하여, 진행 중인 교육훈련 프로그램의 일반적 내용은 다음과 같습니다.</span></span></span></p>

<p><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--></p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><strong>&nbsp; 1. 교육훈련 프로그램의 구성</strong></span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 1) 품질문서 검토 및 보완</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 2) 품질경영시스템 현황 점검 (제조소 방문)</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 3) 교육훈련(Training Program)</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; (1) 의료기기 법규의 요구사항 이해</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; (2) 품질경영시스템의 운영 및 유지 방안</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; (3) 품질문서의 보완사항에 대한 기술지원</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 4) 모의심사 진행</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; (1) 품질문서 및 기록 상태의 점검</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; (2) 제조소 시설(보관소 등) 및 운영 현황 점검</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> </span><!--![endif]--><!--![if--></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#696969;">&nbsp; <strong>2. 교육 일정(소요 기간)</strong></span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 1) 품질문서 검토 및 보완 : 2~4주</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 2) 품질경영시스템 현황 점검(제조소 방문) : 1일</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 3) 교육훈련(Training Program) : 1~2일</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; (1) 의료기기 법규의 요구사항 이해</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; (2) 품질경영시스템의 운영 및 유지 방안</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; (3) 품질문서의 보완사항에 대한 기술지원</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; 4) 모의심사 진행 : 1일</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; (1) 품질문서 및 기록 상태의 점검</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp; (2) 제조소 시설(보관소 등) 및 운영 현황 점검</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p>&nbsp;</p>

<p><span style="color:#696969;">교육훈련 프로그램의 구성은 의뢰회사의 상황과 요구에 따른 새로운 구성도 물론 가능합니다.</span></p>

<p><span style="color:#696969;">교육훈련을 통해 함께 문제점을 고민하고 해결하는 좋은 계기가 만들어지기를 기대해 봅니다.</span></p>

<p><span style="color:#696969;"><!--[endif]--> <!--![endif]--><!--![if--></span></p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><!--[if--><!--[endif]--></span><span style="color:#696969;"><span style="color:#000000;">감사합니다.</span></span></p>

<p><!--[if--><!--[endif]--></p></div>]]></description>
						<pubDate>Tue, 13 Dec 2022 18:59:07 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[의료기기 사이버보안(Cybersecurity)의 적용과 이해]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/1993</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/1993</guid>
						<comments>https://www.ramedi.kr/xe/1993#comment</comments>
									<description><![CDATA[<div class="xe_content"><p><span style="color:#696969;"><strong>1. 목적</strong></span></p>

<p><span style="color:#696969;">&nbsp; 의료기기의 사이버보안 위협사례(해킹, 정보 유출 등)로부터 통신이 가능한 의료기기의 안전관리를 확보하는 데 있다.</span></p>

<p><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></p>

<p><!--[if--><!--[endif]--></p>

<p><span style="color:#696969;"><strong>2. 적용 범위</strong></span></p>

<p><span style="color:#696969;">&nbsp; 유&middot;무선 통신(Wi-Fi, 블루투스, USB, RS-232, LAN 등)을 사용하거나 통신 경로가 존재하는 의료기기에 적용한다.</span></p>

<p><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></p>

<p><!--[if--><!--[endif]--></p>

<p><span style="color:#696969;"><strong>3. 사이버보안 기본원칙</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 의료기기의 사이버보안을 보장하기 위하여 가용성, 기밀성, 무결성이 준수되어야 한다.</span></p>

<p><span style="color:#696969;">&nbsp; 2) 제조자가 품질시스템에서 수립한 위험관리 프로세스 내에서 적용되어야 한다.</span></p>

<p><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></p>

<p><!--[if--><!--[endif]--></p>

<p><span style="color:#696969;"><strong>4. 사이버보안 요구사항의 주요 항목</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 보안 통신</span></p>

<p><span style="color:#696969;">&nbsp; 2) 데이터 보호</span></p>

<p><span style="color:#696969;">&nbsp; 3) 기기 무결성</span></p>

<p><span style="color:#696969;">&nbsp; 4) 사용자 인증</span></p>

<p><span style="color:#696969;">&nbsp; 5) 소프트웨어 유지보수</span></p>

<p><span style="color:#696969;">&nbsp; 6) 물리적 접근</span></p>

<p><span style="color:#696969;">&nbsp; 7) 신뢰성 및 가용성</span></p>

<p><!--[if-->&nbsp;<!--[endif]--> <!--![endif]--><!--![if--></p>

<p><!--[if--><!--[endif]--></p>

<p><span style="color:#696969;"><strong>5. 사이버보안의 적용</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 사이버보안 위험관리 과정을 통해 위해요인을 파악하고, 발생 가능한 위해를 최소화 및 차단하기 위한 설계변경 등의</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp;통제조치를 실행한다.</span></p>

<p><span style="color:#696969;">&nbsp; 2) 위험관리 과정에서 식별된 위해요인에 대한 통제조치의 결과를 소프트웨어 검증 및 유효성 확인의 단계에서 검증하며,</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp;소프트웨어 검증 및 유효성 확인의 자료에는 사이버보안 요구사항에 대한 시험 및 검증 절차, 시험 결과를 포함하여야 한다.</span></p>

<p><span style="color:#696969;">&nbsp; 3) 사이버보안 위험관리 문서와 소프트웨어 검증 및 유효성 확인 자료를 바탕으로 사이버보안 요구사항 체크리스트 작성하여,&nbsp;</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; &nbsp;사이버보안 요구사항이 개발 제품에 적용되었음을 점검한다.</span></p>

<p><span style="color:#696969;"><!--[if-->&nbsp;</span><!--[endif]--> <!--![endif]--><!--![if--></p>

<p><!--[if--><!--[endif]--></p>

<p><span style="color:#696969;"><strong>6. 허가 및 심사 첨부자료</strong></span></p>

<p><span style="color:#696969;">&nbsp; 1) 의료기기 사이버보안 요구사항 체크리스트</span></p>

<p><span style="color:#696969;">&nbsp; 2) 체크리스트의 요구사항에 대한 검증을 확인할 수 있는 자료</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (1) 소프트웨어 검증 및 유효성 확인 자료</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (2) 사이버보안 위험관리 문서</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (3) 성능 시험성적서</span></p>

<p><span style="color:#696969;">&nbsp; 3) 사이버보안 요구사항의 미적용 근거를 확인할 수 있는 자료 (해당되는 경우)</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (1) 사이버보안 위험관리 문서</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (2) 사용설명서</span></p>

<p><span style="color:#696969;">&nbsp; &nbsp; (3) 설계문서 등</span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p>감사합니다.</p>

<p><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--><!--![endif]--><!--![if--></p></div>]]></description>
						<pubDate>Fri, 19 Aug 2022 15:41:53 +0900</pubDate>
								</item>
				<item>
			<title><![CDATA[의료기기 시장(Medical World)의 이해]]></title>
			<dc:creator><![CDATA[라메디]]></dc:creator>
			<link>https://www.ramedi.kr/xe/1961</link>
			<guid isPermaLink="true">https://www.ramedi.kr/xe/1961</guid>
						<comments>https://www.ramedi.kr/xe/1961#comment</comments>
									<description><![CDATA[<div class="xe_content"><p id="SE-a3b34417-d399-4ecf-bcdb-40e0cbd70858"><span style="color:#696969;"><strong>1. <span style="font-size:14px;">메디칼 월드(Medical World)의 개념도</span></strong></span></p>

<div data-hjsonver="1.0" data-jsonlen="6227" id="hwpEditorBoardContent"><img src="http://www.ramedi.kr/xe/files/attach/images/147/961/001/b3653c77bd73fda9a6029a8154ed4e12.jpg" alt="Medical World.jpg" style="" />
<p>&nbsp;</p>

<p>&nbsp;</p>

<p><span style="color:#696969;"><b>2. </b><strong><span style="font-size:14px;">메디칼 월드(Medical World)의 요건</span></strong></span></p>
</div>

<p><span style="color:#808080;">&nbsp; 메디칼 월드로의 진입을 위해서는 다음의 민원업무가 우선적으로 완료되어야 합니다.</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; 1) GMP 적합성인정</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; &nbsp; 제조소의 품질경영시스템이 의료기기 제조 및 품질관리기준에 따라 수립, 실시 및 유지되고 있는지에 대한 심사입니다.</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; 2) 제조업허가</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; &nbsp; 제조소의 최고경영자 및 시설에 관한 기본적인 내용을 심사합니다.</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; 3) 제조품목허가</span></p>

<p><span style="color:#808080;">&nbsp; &nbsp; &nbsp; 제조소에서 생산한 제품에 대하여 그 안전성과 유효성을 심사합니다.</span></p>

<p>&nbsp;</p>

<div data-hjsonver="1.0" data-jsonlen="8560" id="hwpEditorBoardContent">&nbsp;</div>

<p id="SE-7170f5b6-acf9-4e6d-934c-c8f7c22a40a0"><span style="color:#696969;"><strong>3. 시판 후 사후관리</strong></span></p>

<p><span style="color:#808080;">&nbsp; 메디칼 월드의 요건을 갖춘 경우, 드디어 판매를 할 수 있습니다.</span></p>

<p><span style="color:#808080;">&nbsp; 판매 후에는 생산 후 정보, 시판 후 시장조사 등의 시판 후 사후관리 활동을 수행하여야 하며, 그 결과는 위험관리, 사용적합성,&nbsp;</span></p>

<p><span style="color:#808080;">&nbsp; 임상평가, 사용설명서 등의 관련 문서에 주기적이고, 적극적으로 Update 되어야 합니다. 더불어, 그 내용은 설계 및 제조과정에</span></p>

<p><span style="color:#808080;">&nbsp; 반영되어야 합니다.</span></p>

<p><span style="color:#808080;"><!--[if-->&nbsp;<!--[endif]--> </span><!--![endif]--><!--![if--></p>

<p><span style="color:#808080;"><!--[if--><!--[endif]--></span></p>

<p><span style="color:#808080;">&nbsp; 즉, 이러한 지속적인 시판 후 사후관리 활동을 통하여, 지속적인 개선이 이루어지도록 해야 합니다.</span></p>

<p>&nbsp;</p>

<p>&nbsp;</p>

<p>감사합니다.<!--![endif]--><!--![if--></p></div>]]></description>
						<pubDate>Fri, 15 Apr 2022 17:42:27 +0900</pubDate>
								</item>
			</channel>
</rss>
